Saltar al contenido
Otra producciónPublicado

De-biasing the Station Start Time

A. Letessier-Selvon

ingles

Resumen

We study the effect of the bias in the shower front arrival time as measured by the surface detector stations. Using the shower front model of GAP 2006-016, we show that the experimental bias in the detector start time can be properly estimated and corrected for. The correction does not change our angular resolution nor the distributions of the angular distance between the SD and the hybrid reconstruction. On the other hand, it modifies the estimated radius of curvature of the SD events, an important parameter for the mass composition studies.

Datos de la publicación

Autores
A. Letessier-Selvon
Tipo
Otra producción
Estado
Publicado
Fecha de publicación
10/07/2006
Tipo de producción
Nota interna da Colaboração Pierre Auger
URL
http://www.auger.org/admin-cgi-bin/woda/gap_notes.pl/
Fecha de publicación
10/07/2006
País
Brasil
Idioma
ingles
Vínculo con tesis
No
Vínculo con beca
No